Skip to content

U-LAB-05 · University · ML-D

Mission Operations, Fault & Recovery

What evidence supports a bounded recovery or policy decision?

Time
60–90 min
Prerequisites
Spacecraft modes, including safe mode · Reading an event timeline
Evidence status
Unit-validated · reduced-order · simulated evidence

Open in MissionLab

These links open existing MissionLab routes. Run the lab there; this page holds the teaching material.

Faculty brief

Students read a bounded fault or protection event, judge the policy response and write a human recommendation with its causal limits.

Prerequisites

  • Spacecraft modes, including safe mode
  • Reading an event timeline

Time and level

60–90 min · University · ML-D

These routes are public software practice. No account or hardware is needed to run them.

Setup

  1. In Mission operations, use the declared experiments 'Fault recovery' (Fault Recovery: Protect, Recover and Resume) and 'Safe-Mode delivery cutoff' (Safe-Mode Delivery Cutoff: Energy Reserve Stops an Eligible Downlink). 'Eclipse survival' is a useful warm-up.
  2. MLX-13 and MLX-11 present the same operations runtime as guided single-case ML-D missions.
  3. Set the intervention level (1–3) students should use.
  4. Only the declared operations cases listed here are available. This lab is not arbitrary fault injection and adds no fault framework.

Expected student evidence

  • The event and state sequence around the fault or cutoff.
  • The policy action taken and when.
  • The declared case identifier.
  • A human engineering recommendation.
  • A causal limitation statement.

Common misconceptions

  • 'Safe mode means the mission failed.' Safe mode protects the energy reserve; the question is what it costs.
  • 'The policy caused the recovery.' The run shows one declared scenario; causal claims need the event sequence.
  • 'Any fault can be injected.' Only the declared operations cases are supported.

Model limitations

  • Not a hardware-correlated battery model or flight EPS qualification.
  • Not flight GNC certification or measured pointing performance.
  • Not operational RF assurance; atmosphere, modem and BER effects are not modelled.
  • Zero measured channels. The operations lab states that measured hardware and flight qualification remain outside this version.
  • Only declared cases are supported; there is no arbitrary or learner-authored fault injection.

Assessment suggestions

  • Ask for the decisive event on the timeline and what the policy protected at that moment.
  • Credit a recommendation that states its own causal limits.
  • Faculty choose weighting and grading; see the rubric template.

Faculty and their institution own official CLO wording, course approval, grading, rubric adoption and accreditation.